UNI-T UT513C 5kV Digital Insulation Resistance Tester Megohmmeter with Bluetooth App & 5TΩ Range


The UNI-T UT513C High-Voltage Insulation Tester is an industrial-grade, microcomputer-controlled diagnostic instrument engineered to evaluate the insulation integrity of heavy-duty power assets.

Generating up to 5000V of output test voltage, it handles massive resistance scales reaching 5.00 Teraohms (5TΩ), making it a critical tool for power utilities, telecommunications, mining operations, and electromechanical installation departments.

Why the UT513C Should Be Used and Preferred

  • Massive Industrial Testing Range:

    Delivers stable, high-voltage outputs up to 5kV and reads ultra-high resistances up to 5TΩ, satisfying stringent testing demands for commercial power grids.

  • Real-Time Bluetooth Automation:

    Eliminates manual paperwork with built-in Bluetooth data sync, allowing technicians to map diagnostics safely via a smartphone app away from the high-voltage arc zone.

  • Advanced Voltage Customization:

    Features 10% stepping voltage control, allowing engineers to ramp up voltages in controlled intervals (50% to 120% of each range) to identify exact dielectric breakdown thresholds.

Measurement Specifications

  • Insulation Resistance Testing:

    Supports test voltages of 250V, 500V, 1000V, 2500V, and 5000V. Primary measurement ranges span up to 5.00 TΩ depending on the selected voltage, with base accuracies typically ranging from ±(5% + 5) to ±(15% + 20).

  • Voltage & Capacitance:

    Measures DC voltage (30V to 1000V), AC voltage (30V to 750V, 50Hz/60Hz), and capacitance (0.01 μF to 15.0 μF) with an accuracy of ±(3% + 5) for voltages.

  • Current & Stepping:

    Tracks leakage current from 0.01 nA to 5.0 mA, provides a ~5.0 mA short-circuit current, and supports stepping voltage regulation (adjusting 50% to 120% of range by 10% steps).

  • Diagnostics & Safety:

    Includes Polarization Index (PI) and Dielectric Absorption Ratio (DAR) testing, automated external voltage interlocks (blocking tests if >36V), and an internal timer ranging up to 99m 59s.

  • Data & Memory:

    Stores up to 999 complete data sets with USB and Bluetooth mobile app transmission, rated at CAT IV 600V.

Core Device Features

  • 01

    Broad High-Voltage Outputs

    Features 5 fixed primary test ranges: 250V, 500V, 1000V, 2500V, and 5000V.

  • 02

    Fine-Tuning Step Voltage

    Adjusts output voltage in 10% steps, allowing precise variable testing.

  • 03

    Comprehensive Automated Diagnostics

    Computes Polarization Index (PI) and Dielectric Absorption Ratio (DAR) automatically.

  • 04

    Capacitance & Current Tracking

    Measures capacitance from 0.01uF to 15.0uF and tracks real-time leakage currents down to 0.01nA.

  • 05

    Dual-Interface Data Logging

    Stores up to 999 data sets internally, supporting both wireless Bluetooth app streaming and wired USB software analysis.

  • 06

    Proactive Safety Interlocks

    Features automatic internal voltage discharge alongside an external voltage sensor that blocks testing if residual voltage exceeds 36V.

General & Mechanical Characteristics

Power Supply:
Industrial 14.8V, 5200mAh rechargeable lithium battery pack.
Safety Class Rating:
CAT IV 600V certified for high-utility transient protection.
Capacity & Build:
Stores up to 999 measurement sets, measures 238 mm x 166 mm x 90.5 mm, weighs approximately 1800g, and features a classic UNI-T black and red housing with CE and UKCA certifications.

Advantages Over Nearest Competitors

  • Wider Resistance Range:

    Reaches up to 5.00TΩ, surpassing baseline models that cap out around 2.00TΩ.

  • Wireless Connectivity:

    Features a built-in Bluetooth transmitter for live field data streaming to mobile apps, improving upon older wired-only variants like the UT513B.

  • Enhanced Driving Power & Capacitance:

    Utilizes a 5.0mA short-circuit loop to rapidly charge large capacitive loads and integrates direct capacitance measurements up to 15.0uF.

Did You Know?

What is 5kV with regards to the UNI-T UT513C?

  • Definition: 5kV stands for 5 kilovolts, which equals 5,000 volts (V) of direct current (DC) test voltage. Read below for why AC voltage is NOT used.
  • What the tester does: This 5kV output voltage is what the UNI-T UT513C pushes into the electrical wire, motor winding, transformer, or switchgear being tested. This high-voltage testing stresses the target insulation to verify if the insulation can safely handle real-world operating loads without leaking current or breaking down.

What is 5TΩ with regards to the UNI-T UT513C?

  • Definition: 5TΩ stands for 5 teraohms. A teraohm is 1,000,000,000,000 Ω (one trillion ohms).
  • What the tester does: This 5TΩ ceiling is the maximum insulation resistance that the UNI-T UT513C can accurately measure. A high resistance value means the tested insulation is healthy and blocking electricity effectively. The 5TΩ range ensures that the UNI-T UT513C can evaluate extremely high-grade, clean, dry insulation on large transformers or long cables without hitting an "overload" error.

What is the Difference?

  • 5kV is the Source (Test Voltage): 5kV is the high voltage applied by the UNI-T UT513C to the cable or equipment under test.
  • 5TΩ is the Result / Measurement Range (Resistance): 5TΩ is the upper limit of the electrical resistance detected by the UNI-T UT513C in response to that applied voltage.

In short: The UNI-T UT513C injects up to 5,000V (5kV) of testing power and measures how much resistance (up to 5,000,000,000,000 ohms or 5TΩ) the target insulation offers against that voltage.

Why Insulation Testing Uses DC Voltage

Standard insulation resistance tests across the industry rely on DC power for three critical reasons:

1

Accurate Resistance Measurements (Ohm's Law):

To measure pure resistance accurately up to the 5TΩ range, the tester must supply a steady, continuous electrical pressure. AC voltage alternates back and forth constantly, which causes capacitive charging currents that interfere with obtaining a stable resistance reading.

2

Safety for the Tester and Equipment:

Continuous DC allows the UNI-T UT513C to safely monitor the insulation's leakage current and execute its controlled automatic discharge function to drain all stored electrical energy safely once the test finishes.

3

Preventing Component Degradation:

Applying 5,000V of AC electricity would subject the equipment's insulation to continuous rapid stress cycling, generating dangerous internal heat that could permanently damage or puncture the windings and cables being tested.