- Actuators
- Adapters
- Air Blowers
- Air Conditioners
- Air Curtains
- Air Purifiers
- Anemometers
- Axial fans
- Ball Valves
- Belimo
- Blowers
- Brackets
- Brass
- Brazing Rods
- Capacitors
- Carrier Parts
- Clamp Meters
- Cleaning Products
- Coatings
- Compressors
- Condensate Pumps
- Connectors
- Contactors
- Copper Capillary
- Copper Coils
- Copper Straight Tubes
- Copper Strainers
UNI-T UT222 2500A True RMS Heavy Duty Industrial Clamp Meter
UNI-T UT222 Professional Digital Clamp Meter | 2500A AC/DC True RMS, Massive 63mm Jaw, Inrush Current & Low Pass Filter | Heavy-Duty Industrial Multi-Tester Clamp Meter
The UNI-T UT222 is a high-capacity, heavy-duty industrial clamp meter engineered for extreme electrical demands, supporting full AC and DC current measurement up to 2500A through its extra-large 63mm jaw, 1000V AC and DC with the plug-in test leads, 60mF capacitance, 1000°C temperature, and 60MΩ resistance on a True RMS digital display.
[fluentform id="1"]
Measurement Specifications
- AC Current (Jaw):
- Up to 2500A
- DC Current (Jaw):
- Up to 2500A
- AC Voltage:
- Up to 1000V
- DC Voltage:
- Up to 1000V
- Resistance:
- Up to 60MΩ
- Capacitance:
- Up to 60mF
- Frequency:
- Up to 60MHz
- Duty Cycle:
- 0.1% to 99.9%
- Temperature:
- -40°C to 1000°C (-40°F to 1832°F)
- Display Count:
- 6000 Counts
- Analog Bar Graph:
- 61-segment high-speed visual bar-graph
Core Device Features
- 01
True RMS
Accurate readings on both AC Voltage and AC Current across non-linear signals.
- 02
Inrush Current Measurement
Captures surge current spikes during heavy motor or industrial load startup.
- 03
Low Pass Filter (LPF)
Filters out high-frequency noise for accurate measurements on Variable Frequency Drives (VFDs) and motor drives.
- 04
AC+DC Measurement Mode
Evaluates combined AC and DC voltage/current components.
- 05
Data Storage / Memory
Onboard memory capable of storing up to 1000 data sets.
- 06
Analog Output Function (I-OUT)
Provides an analog signal output for monitoring current waveforms via oscilloscopes or data loggers.
- 07
Relative Mode & Zero Mode
Quick zero-point alignment for DC current measurements and relative value testing.
- 08
Data Hold / MAX & MIN
Freeze display values and track maximum and minimum signal spikes.
- 09
Diode & Continuity Testing
Integrated diode testing and audible continuity buzzer.
General & Mechanical Characteristics
- Jaw Opening: Massive 63mm jaw diameter, designed to easily clamp around large busbars, heavy industrial cables, and thick conductor bundles.
- Display Size: 43mm x 30mm display area featuring full icon display.
- Product Dimensions & Weight: Measures 298mm x 107mm x 47mm and weighs 726g.
- Power Source: Standard 9V Battery (6F22).
- Standard Accessories: Includes test leads, output cable (for I-OUT analog output), thermocouple temperature probe, and a rugged industrial tool box.
Advantages Over Nearest Competitors
When evaluated against competing heavy-industrial clamp meters in the 2000A–2500A class:
- Massive 2500A AC/DC Capability: Offers an extended 2500A range for both AC and DC current directly via the clamp jaw, outperforming standard 2000A industrial meters.
- Extra-Large 63mm Jaw Opening: Accommodates high-capacity commercial busbars and large multi-conductor cables without strain.
- Integrated I-OUT Analog Signal Output: Includes a dedicated analog output port and output cable, allowing technicians to pipe real-time current wave data directly into external recording equipment or oscilloscopes.
- Massive Onboard Data Storage (1000 Sets): Holds up to 1000 logs directly in memory, eliminating the need for manual record-keeping during extensive site audits.
- High-Frequency & High-Capacitance Ranges: Supports frequency testing up to 60MHz and capacitance up to 60mF, expanding troubleshooting across electronic drives and filter banks.
- Superior Cost-to-Performance Ratio: Offers a full suite of premium industrial functions—including Inrush, Low Pass Filtering (LPF), AC+DC, 2500A AC/DC, and a hard tool case—at a significantly lower capital expenditure than traditional tier-1 brand equivalents.
Why Duty Cycles Matter for the UT222?
The 0.1% to 99.9% duty cycle tells you exactly how long an electrical signal stays turned "on" versus "off" during operation.
The UT222’s extreme 0.1% to 99.9% range allows industrial technicians to track electrical pulses running at near-zero power or near-maximum output. This is critical for modern industrial setups, as equipment like Variable Frequency Drives (VFDs) and motor controllers regulate power by chopping signals into these precise "on/off" pulses.
With this wide measurement window, the UT222 delivers the precise sensitivity required to troubleshoot, calibrate, and monitor advanced automation systems at any load level.
Why the UT222 Needs Low Pass Filter (LPF)?
Modern industrial equipment—especially Variable Frequency Drives (VFDs), motor controllers, and inverter systems—regulates power by rapidly chopping up voltage signals. This chopping process creates massive amounts of high-frequency "electrical noise" and distortion.
Without LPF: A standard meter gets confused by this high-frequency noise. The numbers on your screen will jump around erratically, giving you a falsely high or inaccurate reading.
With LPF Activated: The UT222 strips away all the erratic high-frequency background noise. It measures only the true, clean fundamental frequency (usually 50Hz or 60Hz) powering the motor.

