INFICON Vortex Dual Refrigerant Recovery Machine

Vortex® Dual sets itself apart by offering a full 1 HP dual piston compressor for the fastest recovery speeds available under real service conditions. A unique micro-channel condenser combined with an oversize fan helps lower discharge pressures resulting in sustained speed in the hottest ambient temperatures. FEATURES
    • 1 HP dual piston compressor for industry leading recovery rates
    • Micro-channel condenser provides exceptional heat exchange allowing Vortex Dual to maintain recovery rates throughout the entire recovery cycle
    • Oversize fan provides exceptional cooling
    • Simple two valve operation
    • Full size protected gauges for both suction and tank pressure
    • Self-purge without the need to change hoses
    • Filter/dryer included
    • Noise absorbing blow molded case
Read More About The INFICON Vortex Dual Refrigerant Recovery Machine

INFICON Wey-tek HD Wireless Charging Scale with Handpiece

Features

Communicates and displays through downloadable free app on your smartphone or tablet or through an optional wireless handpiece
Bluetooth range of 30 ft. (10 m)
Measures in pounds/ounces, kilograms/grams, decimal pounds, or ounces only
Large, durable, non-skid weighing platform
Industry first alarm mode indicates when a programmed target refrigerant charge is reached
Job log function tracks refrigerant transferred; log file can be emailed from your smart phone for analysis or record keeping (app only function)
Auto-shutoff to maximize battery life
High accuracy load cell won't drift
Hard plastic carrying case included

Handpiece features

Can be used in lieu of Smart phone via Bluetooth transmission Large, vivid, color display is easy to read, even in direct sunlight Auto-shutoff and screen dimming in user-selectable intervals to preserve battery life Magnet on handpiece for placing on a tank or other nearby objects for easily accessible display

INFICON WeyTek weighing scale

Accurate and reliable readings for years to come

The Wey-TEK Refrigerant Charging Scale truly is Laboratory Accurate and Toolbox Tough. Simple operation, outstanding durability, and great accuracy make Wey-TEK a great choice for any technician. A large weighing platform, 220 lb. (110 kg) capacity, and competitive price make Wey-TEK a great value. See why Wey-TEK is the most requested refrigerant scale on the market.

INFICON Whisper ultrasonic leak detector

Ultrasonic Leak Detector - Versatility and flexibility for a variety of applications The INFICON Whisper ultrasonic leak detector has an internal noise control system that ensures the instrument remains unaffected by audible noise. This makes the Whisper a versatile tool that can even be used in noisy environments, such as mechanical rooms.

Johnson Controls Thermowell TE-6300W Series

Thermowells are used in conjunction with remote probe style temperature sensors where thermowell insertion into a vessel or container to sense temperature is required. The TE-6300W thermowells are available in stainless steel, brass body and copper bulb, and direct mount (no adaptor) style.
johnson controls TE-6300W thermowell

EH110 Contactor, 110V 50Hz coil, with built-in 2NO+2NC auxiliary contacts

  • HVAC OEM Contactor EH110
  • 110 Amperes
  • 110V 50Hz coil
  • with built-in 2 NO + 2 NC auxiliary contacts
  • for York chiller
(1 NO + 1 NC auxiliary contacts for each side) Click To Download The Specifications

EH145 Contactor, 110V 50Hz coil, with built-in 2NO+2NC auxiliary contacts

  • HVAC OEM Contactor EH145
  • 145 Amperes
  • 110V 50Hz coil
  • With built-in 2 NO + 2 NC auxiliary contacts
  • for York chiller
(1 NO + 1 NC auxiliary contacts for each side) Click To Download The Specifications

EH210 Contactor, 110V 50Hz coil, with built-in 2NO+2NC auxiliary contacts

  • HVAC OEM Contactor EH210
  • 210 Amperes
  • 110V 50Hz coil
  • With built-in 2 NO + 2 NC auxiliary contacts
  • for York chiller
(1NO+1NC auxiliary contacts for each side) Click To Download The Specifications

York Chiller Parts (Johnson Controls TE-6352M-1 sensor)

These sensors are mainly used in York chillers to detect the temperature of the water The Johnson Controls TE-6300 Temperature Sensor line provides economical solutions for a wide variety of temperature sensing needs, including wall-mount, outdoor-air, duct, strap-mount, well-insertion, duct-averaging, and VAV Modular Assembly (VMA) flange-mount duct-probe applications. The TE-6300 line offers both a metal and a plastic enclosure for the most popular models.
johnson controls sensors

York Chiller Parts (Johnson Controls TE-635AM-2 sensor)

These sensors are mainly used in York chillers to detect the temperature of the water The Johnson Controls TE-6300 Temperature Sensor line provides economical solutions for a wide variety of temperature sensing needs, including wall-mount, outdoor-air, duct, strap-mount, well-insertion, duct-averaging, and VAV Modular Assembly (VMA) flange-mount duct-probe applications. The TE-6300 line offers both a metal and a plastic enclosure for the most popular models.