Kriwan 22A634 INT69 Y Diagnose

Brief Introduction of This Model 1) Perfect for screw and scroll compressors. This motor protector is mainly employed on compressors of which the motor's direction of rotation is essential for the function. 2) Protects from high temperature and phase issues (inversion, asymmetry, missing, etc.). 3) Diagnose datalog function 4) UL approved model Used in high volume by Danfoss, Trane, Hanbell and many Chinese OEMs.
Application

The compressor protection Kriwan 22A634 INT69 Y Diagnose is a further development of the reliable KRIWAN motor protectors. Additional inputs for the phase monitoring as well as supplementary flexible-response protective functions help to improve the availability and extend the service life of a refrigeration system.

The Kriwan 22A634 INT69 Y Diagnose automatically saves operational and error data in a non-volatile memory. This data can be retrieved and analysed for diagnosis. The full scope of the diagnosis is achieved by using a KRIWAN-specific AMS sensor.

This motor protector is mainly employed on compressors of which the motor's direction of rotation is essential for the function.
kriwan 22A634
Functional Description

The temperature monitoring in the motor winding is done according to the static evaluation process; the motor is switched off immediately if the nominal response temperature of the built-in AMS or PTC sensors is reached.

A short circuit at an AMS or PTC input also leads to a switch-off. A short cycling leads to a reset delay.

Following cooling off and/or error rectification and subsequent restart delay, the compressor may be restarted. Restart after a lock-out is only possible after a reset.

The phase monitoring of the motor voltage is active 1s after the start of the motor. The correct phase sequence is monitored for 5s, the phase failure is monitored for the total motor running time. If a wrong phase sequence is detected, the motor protector will lock switch off, if there is a phase failure then a switch-off takes place.

After motor stop, the phase monitoring is deactivated for approximately 15s to prevent unintended locking due to brief reverse running of the compressor.

For operation in the specified manner, the supply voltage has to be on permanently on the Kriwan 22A634 INT69 Y Diagnose.

The built-in LED signals the current status of the motor protector (see flash code).
Compressor Motor Protectors

Replaces Goldair 22A282 OUT69 Y Motor Protector

Lau Fan Blades

Get unbeatable prices on authentic Lau fan blades that are made in USA. Please do hurry as these prices are only valid on existing stocks.
Model Description
60717101 LAU fan 16" CW 3 Leaves
60760601 LAU fan 16" CCW 4 leaves
60760501 LAU fan 16" CW 4 Leaves
6130500001 LAU fan 18" CW 2 Leaves
60556101 LAU fan 18" CW 3 Leaves
60558501 LAU fan 18" CW 4 Leaves
6130560001 LAU fan 20" CW 2 Leaves
60559501 LAU fan 22" CW 4 Leaves
60559601 LAU fan 22" CCW 4 Leaves
60560001 LAU fan 24" CCW 4 Leaves
60761501 LAU fan 26" CW 5 leaves for TRANE OEM
60835801 LAU fan 8" CW 5 Leaves 5/16" Bore
60835901 LAU fan 8" CCW 5 Leaves 5/16" Bore
60833101 LAU fan 28" CW 4 Leaves
60556701 LAU fan 20" CW 3 Leaves
60556801 LAU fan 20" CCW 3 Leaves
60557401 LAU fan 22" CCW 3 Leaves
61093601 LAU fan 30" CW 3 Leaves