- Actuators
- Adapters
- Air Blowers
- Air Conditioners
- Air Curtains
- Air Purifiers
- Anemometers
- Axial fans
- Ball Valves
- Belimo
- Blowers
- Brackets
- Brass
- Brazing Rods
- Capacitors
- Carrier Parts
- Clamp Meters
- Cleaning Products
- Coatings
- Compressors
- Condensate Pumps
- Connectors
- Contactors
- Copper Capillary
- Copper Coils
- Copper Straight Tubes
- Copper Strainers
WIPCOOL WPO-3 Vacuum Pump Oil
Only for 20CFM or more vacuum pumps
Higher Flash Point of 268°C.
Pour Point of -°16C
For Your Information, please note the following:
What is Flash Point?
Flash point is the lowest temperature at which a liquid's vapors can ignite with a brief flame, but do not sustain a fire. It's a key safety measure indicating a substance's flammability and is influenced by factors like apparatus design and the surrounding air. A lower flash point indicates a higher flammability risk.
What is Pour Point?
The pour point is the lowest temperature at which a liquid, such as a petroleum product or lubricant, will flow or pour under specific test conditions. It is an important property that indicates how well a substance will perform in cold environments, as a substance below its pour point will solidify and not be able to flow through pipelines or reach critical components in machinery.
Siemens RDF600KN Thermostat
Flush-mount room thermostat with LCD for fan coil units and compressors in DX-type equipment
- KNX communications
- For heating and/or cooling applications
- 2 or 3-position control outputs
- Output for 1-speed or 3-speed fan
- 2 multifunctional inputs for keycard contact, external room / return air temperature (QAH11.1, QAA32), heat / cool changeover, operation mode changeover, window contact on/off, dewpoint monitor, electrical heater enabled, fault contact, presence detector
- Operating modes: Comfort, Economy and Protection
- Automatic or manual heating/cooling changeover
- Adjustable commissioning and control parameters
- Minimum and maximum setpoint limitation
- Backlit display
- Color of housing: signal white (RAL 9003)
- Independent function for window contact, presence detector (standard presence and hotel presence)
Siemens RDF600T Thermostat
Flush-mount room thermostat for round conduit box with LCD for fan coil units and compressors in DX-type equipment
- Output for 1-speed or 3-speed fan
- 2 or 3-position control outputs
- Two multi functional inputs for key card contact, external room / return air temperature (QAH11.1, QAA32), heat / cool changeover, operation mode changeover, window contact on/off, dewpoint monitor, electrical heater enabled, fault contact
- Operating modes: Comfort, Energy Saving and Protection
- Automatic or manual heating/cooling changeover
- Adjustable commissioning and control parameters
- Minimum and maximum set point limitation
- With infrared receiver for remote control, remote control not included.
- Color of housing: signal white (RAL 9003)
- 8 Timers with a 7-day programmable schedule
- Backlit display>
Siemens RDF800KN Thermostat
- KNX communications
- 3 multi-functional inputs for keycard contact, external room / return air temperature (QAH11.1, QAA32), heat / cool changeover, operation mode changeover, window contact on/off, dew point monitor, electrical heater enabled, fault contact
- Operating modes: Comfort, Economy and Protection
- 2-position, 3-position or PWM control outputs
- Automatic or manual fan speed for 1-speed, 3-speed fan
- Automatic or manual heating / cooling changeover
- Adjustable commissioning and control parameters
- Minimum and maximum set point limitation
- Backlit display
Kriwan 22A298 Delta-P II Electrical Part For Level Monitoring The Lubrication System
KRIWAN level monitoring offers different sensor versions for the monitoring of the liquid level in refrigerant compressors, oil and refrigerant receivers and oil separators.
replaces Emerson model 3164918Â
Monitoring of the minimum / maximum liquid level
APPLICATION
Universally applicable for oil management in systems with conventional refrigerants and lower temperature requirements
Kriwan 22D630 = 22S630 Delta-P II Electrical Part Differential Pressure Sensor + 02D555 screw in part
For Bock, Frascold, Dorin
Application of 22S630 Delta-P II Electrical Part Differential Pressure Sensor
Monitoring the lubrication system is especially important in refrigerant compressors.
A very reliable method for piston compressors is the KRIWAN differential pressure monitoring.
It consists of two components: the DELTA-P II evaluation part and a separately available screw-in part.
The electronic evaluation part can be mounted or replaced without having to open the refrigeration circuit.
Kriwan 22S571 Delta-P2 Differential Pressure Control + DELTA-P 02D555 screw-in part
replaces Bitzer model 34731711
APPLICATION
Monitoring the lubrication system is especially important in refrigerant compressors.
A very reliable method for piston compressors is the KRIWAN differential pressure monitoring.
It consists of two components: the DELTA-P II evaluation part and a separately available screw-in part.
The electronic evaluation part can be mounted or replaced without having to open the refrigeration circuit.